Customization: | Available |
---|---|
Certification: | ISO, CE |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MITSUBISHI ELECTRIC TENSION CONTROLLER LM-10TA
Item | Specifications | ||
Power | Input | DC24V±15% power about 0.2A | |
Output | Power supply for tension detector Up to 2 LX-TD tension detectors can be connected | ||
Output signal | Tension signal............. When measuring tension, it can be adjusted in the range of DC(0~5)~(0~10)V Recorder signal.............. When measuring tension, it can be adjusted in the range of DC(0~5)~(0~10)V Signal for peripheral tensiometer.......... DC1mA galvanometer Load resistance: less than 300 |
||
Adjusting potentiometer | Zero, span adjustment with (4)} into the adjustment window Peripheral tension meter (1) |
||
WT | about 200g | ||
Installation method | Screw fixation,DIN rail | ||
Environmental specification | Operating ambient temperature | 0~55ºC | |
Ambient humidity | 35~85%RH | ||
anti-vibration | 10~55Hz 0.5mm(Max 19.6m/s2) 2 hours in each of the three axis directions | ||
Impact resistance | 98m/s2 3 times in each direction of the 3 axes | ||
Power supply noise tolerance | According to the noise voltage 1000Vp-p noise amplitude 1μs frequency 30~100Hz noise simulation device | ||
Insulation resistance | Use DC500V megohm meter,5M or more | ||
ground | Type D grounding | ||
Use environment | No corrosive gas, conductive dust, no dust. No rain, water contact environment. |