Made in China JULONG NT6-RG22-2 Photocell Sensor For Packing
Operation:
Firstly, select the output state(Dark switching or Light switching), then to adjust the sensitivity.
1. Darking switching output adjustment methods:
1. Turn the output option switch to dark switching, (no matter the spot aims at dark color or light color ) clockwise the sensitivity rotary knob to light the indicator light( light on means control output on, otherwise output shut off. )
2. Aim the spot at dark color piece(color code), adjust sensitivity knob, indicator light on, remember the position A this knob turned.
3. Then aim the spot at the light color piece(bottom color), clockwise adjust the knob, indicator light on, remember the position B this knob turned.
4. Finially, put the knob back to the middle place between A and B.
Note: because this sensiivity control is multiturn potentiometer, when adjusting, you need to remember the position A and B, as well as remember how many rounds from A to B, and how many rounds when back to the middle of A and B.
2. Light switching output adjustment methods:
1. Turn the output option switch to light switching, (no matter the spot aims at dark color or light color ) anticlockwise the sensitivity rotary knob to light the indicator light
2. Aim the spot at light color piece(bottom color), adjust sensitivity knob, indicator light on, remember the position A this knob turned.
3. Then aim the spot at the dark color piece(color code), anticlockwise adjust the knob, indicator light on, remember the position B this knob turned.
4. Finially, put the knob back to the middle place between A and B.
Note: because this sensiivity control is multiturn potentiometer, when adjusting, you need to remember the position A and B, as well as remember how many rounds from A to B, and how many rounds when back to the middle of A and B.
Technical Data:
Detection Mode |
Coaxial Reflective |
Detect Distance |
10mm +/- 2mm |
Supply Voltage |
DC10-30V +/-10% Ripple:<10% |
Current Consumption |
Under 45 mA |
Light Source Spectrum |
Red, green, blue, white are optional |
Light-spot |
Round and rectangular facula are optional |
Detection Angle |
Light and surfaces to be tested: 90 degree; allowable deviation +/-15 |
Response Time |
50μs |
Output Mode |
Light switching and dark switching output |
Output Indication |
Red LED |
Output Voltage |
High level Vs-(≤1.5); low level (≤1.2V) |
Bring Load Current |
200mA |
Analog Output |
0-10mA |
Circuit Protection Devices |
Vs Voltage have reverse polarity protection, Output short-circuit protection. When load current 1>200mA, the switch will tripping off automatically, when 1<200mA, signal automatic recovery, at the same time, it owns wrong connectors wire protection. |
Sensitivity |
Multiturn adjustable |
Level of Protection |
Lp67 (Moistureproof and dustproof) |
Environment Temperature
|
Operation:-15-55ºC; storage: -25~80ºC |
Material |
Metal |
Outgoing Line |
Φ5.4PVC round core sheath shield cable; standard length: 2M |
Contact Us: