Basic Info.

Model NO.
LM-10PD
Tension Detection Output
Set Value: 0~2000n, X10n
External Tension Meter Used Output
DC1ma(Internal Impedance 1.5 Ohm or Below
Record Meter Used Output
Output Voltage: 0~5V
Display
Full Scale Set: 0.01~20000n
Ambient Temperature
0~50 Celcius Degree
Ambient Humidity
35~80%
Transport Package
Carton Box
Specification
LM-10PD
Trademark
Mitsubishi
Origin
Japan
HS Code
9032899090
Production Capacity
3000 PCS / Month

Product Description

MITSUBISHI TENSION LM-10PD  (tension table)

LM-10PD tonometer used to get significantly in the detector from the LX-TD tension and strain ceremony pass salty Zhang, wire, various film unwinding, rewinding and intermediate shaft so the tension signal, whilethe instrument the apparatus of the amplified signal output to the recording apparatus, the peripheral tension meter, programmable controller, etc.
 
Feature:
1. Compared with the company's previous models, greatly realized Product miniaturization, lightweight
2. Automatic zero, span adjustment: a key type tension detection zero, span adjustment
3. Parameters set number officer
4. Tension lower limit on detection function (2 point detection)
5. Tension peak memory function
6. Supporting the use of the Strain ceremony sensor
7. The output filter can adjust alone
8. Can manually display, output bias and span adjustment
 
Specifications
  Power Supply       AC85~264V     50/60HZ     50VA
 Tension signal output ·Voltage output: 0~5V,0~10V,1~5V/FS     
·Load resistance:1 k Ω or above
·Current output: 4~20mA/FS                 
·Load resistance:500 Ω or below
Tension detection output  ·Set value: 0~2000N,   X10N
 ·pen-collector output: DC30V/0.5A
   External tension meter used output ·DC1mA(Internal impedance 1.5KΩ or below)
Record meter used output ·Output voltage: 0~5V                        
·Load resistance: 10KΩ or above
Display ·Full scale set: 0.01~20000N
 ·unit:  N or X10N
Working environment  ·Ambient temperature:       0~50ºC
 ·Ambient humidity:     35~80%
 ·Vibration:       Less than 0.5 G