Mitsubishi Tension Controller Le-50pau

Product Details
Customization: Available
Certification: CE
Condition: New
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (13)
  • Mitsubishi Tension Controller Le-50pau
  • Mitsubishi Tension Controller Le-50pau
  • Mitsubishi Tension Controller Le-50pau
  • Mitsubishi Tension Controller Le-50pau
  • Mitsubishi Tension Controller Le-50pau
  • Mitsubishi Tension Controller Le-50pau
Find Similar Products

Basic Info.

Model NO.
LE-50PAU
Working Mode
Continuous
Installation
Vertical
Usage
Paper Machinery, Packing Machinery, Ship, Elevator, Stage Machinery, Machine Tool, Food Machinery, Chemical Machinery, Construction Machinery, Metallurgical Machinery
Power Source
Electromagnetic
Place Original
Japan
Power
AC100~240V 50/60Hz 400va
Rated Output
DC24V 4A
Subsidies Output
DC10V 2A Within 30sec
Model
Le-50pau
Product Name
Tension Controller
Specifications
as Described in Chapter-2 of This Manual, The Pow
Transport Package
Carton Box
Specification
LM-10PD
Trademark
MITSUBISHI
Origin
Japan
HS Code
9032899090
Production Capacity
50 PCS Per Month

Product Description

                MITSUBISHI ELECTRIC TENSION CONTROLLER LE-50PAU
Product name:TENSION CONTROLLER
Real Estate: Japan
Brand: MITSUBISHI
Model: LE-50PAU

Specifications
Main applications
< Power amplifier for tension control >
• The power amplifier is used in combination with the closed-loop type tension control unit such as
LE-40MTA-E, LE-40MTB-E, LE-30CTN, etc. tension control unit to amplify the output signal or such control unit, and to apply the power source to the excitation coil of clutch / brake.
< Manual power source, using external setting type valuable resistor >
• The power amplifier will appear to be a variable current ( or variable voltage ) power source, using
manual operation simply by connecting the variable resistor (8V, 2kW ) to the imput terminal of this
power amplifier.
Since the non-linearity compensation is executed, the opration is easy.
< Semi-automatic tension control unit >
• As described in chapter-2 of this manual, the power amplifier can be also used as semi-automatic
tension control unit by using the LE-5AP operator panel in combination.
• the semi-automatic tension control unit is provided with winding diameter detection function whitch
is intended to ensure the desired tension by controlling the output current automatically in accordance
with the winding diameter. It can ensure the simplified open-loop control in whitch no tension
tetector is used.
• Using the LE-5AP operator panel described previously will also allow the basic characteristeic of
power amplifier to be set easily.

 
Mitsubishi Tension Controller Le-50pau
Mitsubishi Tension Controller Le-50pau

Specifications
Item Specifications
Power Supply Input AC100~240V (-15~+10%) 50/60Hz  Power 400VA  Built-in power fuse 250V 8A Surge current 50A300ms
  Output Potentiometer power--DC8V   Potentiometer resistance: 2 k Ω above
Scroll sensor with the power source --DC12V   15 mA below
Contact signal Input start -ON→OFF,Stop the clock began to work, start inertia protection
Output remote control---ON :Output start,OFF:Output stop
Aux Out ON/OFF-----------ON: Begin to Aux Out
DC12V  5mA / 1 internal power supply
  Analog signal Input Control signal ----0~8V  Internal resistance:22 KΩ
  Output Power amplifier output --- DC24V   4A above
Aux Out-DC10V   2A below  Within 30 seconds  Load resistance:4.8 Ωbelow    
   Weight About 2.5kg   
 Installation method   The ground, metope installed
 Features   Constant current, constant voltage control, torque nonlinear compensation function, stop timer, stop gain, stop bias
Environment Ambient Temp 0~55ºC
  Ambient Humidity 30~85%RH (No gel)
  Shock resistant 10~55 Hz  0.5(Max19.6m/s²) Three axis directio each 2 times
  Impact resistance 98 m/s²  Three axis directio each three times
  Power supply Noise tolerance According to the noise voltage 1000 vp - p, noise width 1 µ s, frequency 30 ~ 100 hz noise simulator Between All terminal  and grounding terminal
  Voltage withstand AC1500V  1 minute  
  Insulation Resistance DC500V  Megohmmeter measurement value is more than 5 m Ω
  Ground Class D grounding line
   Use environment No corrosive gas, flammable gas, electrical conductivity dust, no dust. No rain, water contact environment